A 0714_A 0713_2102016_020617.mp4
2 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - LONG & CIRCUM REBAR
2 ft. - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG
7.3 ft. - General Observation - WATER LEVEL DROPS AT 8'
8 ft. - General Observation - FLOW DROPS -POSSIBLE CONCRETE UNDER FLOW
8 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES - LONG & CIRCUM REBAR
16.8 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES
84.6 ft. - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG
93.3 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE
93.3 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG
103.7 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES
163.7 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES - PEELING LAITANCE COAT
| Distance | Code | Observation |
|---|---|---|
| 103.6 | SAV | SEVERE AGG SPORATIC |
| 207.7 | AMH | 2:40AM |
| 163.7 | SSS | PEELING LAITANCE COAT |
| 2 | SRC | LONG & CIRCUM REBAR |
| 93.3 | SSS | BLISTERING PEELING CONCRETE |
| 2 | SAM | SEVERE AGG |
| 103.6 | SAV | — |
| 84.6 | SAM | SEVERE AGG |
| 0 | MWM | — |
| 0 | MWL | — |
| 16.8 | SRC | — |
| 8 | MGO | FLOW DROPS -POSSIBLE CONCRETE UNDER FLOW |
| 84.6 | SRC | — |
| 0 | AMH | 205:AM |
| 93.3 | SAM | — |
| 207.2 | SAV | SEVERE AGG SPORATIC |
| 103.7 | SSS | — |
| 8 | SRC | LONG & CIRCUM REBAR |
| 7.3 | MGO | WATER LEVEL DROPS AT 8' |
| 93.3 | SAV | SEVERE AGG |
| 84.6 | MWL | — |
| 207.2 | SSS | — |