05 2208_05 2203_252016_011219.mp4
2 ft. - Shape or Size Change, -, 12" - PIPE APPEARS 12"VCP START
2 ft. - Shape or Size Change, -, 12" - 12" VCP
6 ft. - Deposits Attached Grease, 15 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start
15 ft. - Deposits Attached Grease, 20 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start
24.2 ft. - Shape or Size Change, -, 12" - 12" VCP FINISH
24.6 ft. - Downstream Manhole, Survey Ends - 1:10AM
| Distance | Code | Observation |
|---|---|---|
| 24.2 | DAGS | — |
| 24.6 | AMH | 1:10AM |
| 15 | DAGS | — |
| 0 | AMH | 12:45AM |
| 2 | MSC | PIPE APPEARS 12"VCP START |
| 2 | FC | SLIGHT |
| 2 | MSC | 12" VCP |
| 15 | DAGS | — |
| 6 | DAGS | — |
| 0 | MGO | MH CONNACTIVE 6:00 |
| 0 | MGO | MH CONN OPEN 9:00 |
| 24.2 | MSC | 12" VCP FINISH |