Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 16, 2021, 08:48 AM
  • B 1277_B 1276_7162021_015351.mp4

Date
07/16/2021
W/O
0896748
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z01126
PipeID
P25172
Time
1:48 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1874
Sewer Name
B JOINT OUTFALL B - UNIT 6J
City
PASADENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
12
Purpose
Capital Improvement Program Assesment
Project
20210715MDM_JOINT_OUTFALL_B_UNIT_6J
Material
Reinforced Concrete Pipe
Shape
Circular
Height
24 in.
Upstream MH
B 1277
Downstream MH
B 1276
Dir. of Survey
Downstream
Length Surveyed
160.9 ft.
Total Length
160.9 ft.
Structural Index
3
Structural Quick
3321
Structural Rating
11
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
13
Pipe schematic from manhole B 1277 to B 1276
MH: B 1277MH: B 1276downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 1:55AM0 ft. MWM - Water Mark, 40 %of cross sectional area2 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - BLISTERING CONCRETE2 ft. SAV - Surface Aggregate Visible, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG2.3 ft. SAP - Surface Aggregate Projecting, from 02 to 03 o'clock, within 8 inches of joint: NO, Start - SEVERE AGG2.3 ft. SAP - Surface Aggregate Projecting, from 09 to 10 o'clock, within 8 inches of joint: NO, Start - SEVERE AGG79.3 ft. RFB - Roots Fine Barrell, from 02 to 03 o'clock, within 8 inches of joint: YES - 3%99.1 ft. MGO - General Observation - MAG COAT 60% START160.2 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - BLISTERING CONCRETE160.2 ft. SAV - Surface Aggregate Visible, from 10 to 02 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG160.2 ft. SAP - Surface Aggregate Projecting, from 02 to 03 o'clock, within 8 inches of joint: NO, Finish - SEVERE AGG160.2 ft. SAP - Surface Aggregate Projecting, from 09 to 10 o'clock, within 8 inches of joint: NO, Finish - SEVERE AGG160.9 ft. AMH - Downstream Manhole, Survey Ends - 2:10AM

Observation photos (5)

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - BLISTERING CONCRETE

    2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - BLISTERING CONCRETE

  • Surface Aggregate Visible, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

    2 ft. - Surface Aggregate Visible, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

  • Surface Aggregate Projecting, from 02 to 03 o'clock, within 8 inches of joint: NO, Start - SEVERE AGG

    2.3 ft. - Surface Aggregate Projecting, from 02 to 03 o'clock, within 8 inches of joint: NO, Start - SEVERE AGG

  • Surface Aggregate Projecting, from 09 to 10 o'clock, within 8 inches of joint: NO, Start - SEVERE AGG

    2.3 ft. - Surface Aggregate Projecting, from 09 to 10 o'clock, within 8 inches of joint: NO, Start - SEVERE AGG

  • General Observation - MAG COAT 60% START

    99.1 ft. - General Observation - MAG COAT 60% START

Observations (14)

DistanceCodeObservation
79.3RFB3%
0MWL
160.2SSSBLISTERING CONCRETE
160.9AMH2:10AM
0AMH1:55AM
2.3SAPSEVERE AGG
160.2SAVSEVERE AGG
2.3SAPSEVERE AGG
2SSSBLISTERING CONCRETE
160.2SAPSEVERE AGG
160.2SAPSEVERE AGG
0MWM
99.1MGOMAG COAT 60% START
2SAVSEVERE AGG

Properties (6)

custom_field_three
SEVERE AGG MISSING
custom_field_two
2
customer
LACSD
datetime
2021-07-16T01:48:30-07:00
documentation
MARTIN,OLIVER 111,REVELES,RAMIERZ
is_lateral_inspection
false