C 0207_C 0206_7142021_034049.mp4
2 ft. - General Observation - MAG COAT 80% START
2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE
17 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING PEELING CONCRETE
51.7 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING PEELING CONCRETE
67 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERIN PEELING CONCRETE
203.7 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING CONCRETE
212.1 ft. - Surface Aggregate Visible, from 02 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG
| Distance | Code | Observation |
|---|---|---|
| 17 | SSS | BLISTERING PEELING CONCRETE |
| 212.1 | SAV | SEVERE AGG |
| 0 | AMH | 3:40AM |
| 312.8 | AMH | 4:05AM |
| 51.7 | SSS | BLISTERING PEELING CONCRETE |
| 0 | MWL | — |
| 2 | MGO | MAG COAT 80% START |
| 0 | MWM | — |
| 203.7 | SSS | BLISTERING CONCRETE |
| 312.3 | MGO | 80% MAG COAT FINISH |
| 312.3 | SSS | BLISTERING PEELING CONCRETE |
| 67 | SSS | BLISTERIN PEELING CONCRETE |
| 2 | SSS | BLISTERING PEELING CONCRETE |