Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 13, 2021, 11:08 AM
  • C 0209_C 0414_7132021_041121.mp4

Date
07/13/2021
W/O
0896123
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00124
PipeID
P09601
Time
4:08 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1870
Sewer Name
C JOINT OUTFALL C - UNIT 3E
City
LONG BEACH
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
19
Purpose
Capital Improvement Program Assesment
Project
20210713MDM_JOINT_OUTFALL_C_UNIT_3E
Material
Reinforced Concrete Pipe
Shape
Circular
Height
27 in.
Upstream MH
C 0209
Downstream MH
C 0414
Dir. of Survey
Downstream
Length Surveyed
42.8 ft.
Total Length
42.8 ft.
Structural Index
2
Structural Quick
2300
Structural Rating
6
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
6
Pipe schematic from manhole C 0209 to C 0414
MH: C 0209MH: C 0414downstream0 ft. AMH - Upstream Manhole, Survey Begins - 4:10AM0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Capped2 ft. MGO - General Observation - MAG COAT 80% START2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE9 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING PEELING CONCRETE12.4 ft. SSS - Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: NO - BLISTERING PEELING CONCRETE42.3 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active42.3 ft. MGO - General Observation - MAG COAT 80% FINISH42.3 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - BLISTERING PEEING CONCRETE42.8 ft. AMH - Downstream Manhole, Survey Ends - 4:20AM

Observation photos (4)

  • General Observation - MAG COAT 80% START

    2 ft. - General Observation - MAG COAT 80% START

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING PEELING CONCRETE

    9 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING PEELING CONCRETE

  • Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: NO - BLISTERING PEELING CONCRETE

    12.4 ft. - Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: NO - BLISTERING PEELING CONCRETE

Observations (12)

DistanceCodeObservation
0AMH4:10AM
42.3MGOConn. @ Mh, 3 O' Clock. Active
42.8AMH4:20AM
9SSSBLISTERING PEELING CONCRETE
0MWL
42.3MGOMAG COAT 80% FINISH
0MWM
2MGOMAG COAT 80% START
0MGOConn. @ Mh, 9 O' Clock. Capped
2SSSBLISTERING PEELING CONCRETE
12.4SSSBLISTERING PEELING CONCRETE
42.3SSSBLISTERING PEEING CONCRETE

Properties (6)

custom_field_three
BLISTERING PEELING CONCRETE 80% MAG COAT
custom_field_two
3
customer
LACSD
datetime
2021-07-13T04:08:57-07:00
documentation
MARTIN,OLIVER 111,BARR,RAMIERZ
is_lateral_inspection
false