Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 17, 2021, 09:01 AM
  • B 0457_B 0456_7172021_021355.mp4

Date
07/17/2021
W/O
0896591
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00093
PipeID
P08970
Time
2:01 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1876
Sewer Name
B JOINT OUTFALL B - UNIT 5C
City
PASADENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
11
Purpose
Routine Assessment
Project
20210717MDM_JOINT_OUTFALL_B_UNIT_5C
Material
Reinforced Concrete Pipe
Shape
Circular
Height
21 in.
Upstream MH
B 0457
Downstream MH
B 0456
Dir. of Survey
Downstream
Length Surveyed
2.5 ft.
Total Length
2.5 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
4
Overall Quick
Overall Rating
4
Pipe schematic from manhole B 0457 to B 0456
MH: B 0457MH: B 0456downstream0 ft. MWL - Water Level, 40 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 2:15AM0 ft. MWM - Water Mark, 50 %of cross sectional area0.4 ft. MGO - General Observation - STOPLOG IN PLACE2 ft. MGO - General Observation - DOWNLEG UPSTREAM SIPHON SOUTH2.5 ft. MSA - Survey Abandoned - DOWNLEG UPSTREAM SIPHON SOUTH

Observation photos (3)

  • General Observation - STOPLOG IN PLACE

    0.4 ft. - General Observation - STOPLOG IN PLACE

  • General Observation - DOWNLEG UPSTREAM SIPHON SOUTH

    2 ft. - General Observation - DOWNLEG UPSTREAM SIPHON SOUTH

  • Survey Abandoned - DOWNLEG UPSTREAM SIPHON SOUTH

    2.5 ft. - Survey Abandoned - DOWNLEG UPSTREAM SIPHON SOUTH

Observations (6)

DistanceCodeObservation
0.4MGOSTOPLOG IN PLACE
0MWL
2.5MSADOWNLEG UPSTREAM SIPHON SOUTH
0AMH2:15AM
0MWM
2MGODOWNLEG UPSTREAM SIPHON SOUTH

Properties (8)

additional_info
DOWNLEG UPSTREAM SIPHON SOUTH
custom_field_three
CIPP GOOD CONDITION
custom_field_two
4
customer
LACSD
datetime
2021-07-17T02:01:57-07:00
documentation
MARTIN,OLIVER 111,BARR,RAMIERZ
is_lateral_inspection
false
lining
CIPP