Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 22, 2021, 08:28 AM
  • B 0439_B 0438_06222021_014139.mp4

Date
06/22/2021
W/O
896722
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00093
PipeID
P08951
Time
1:28 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8950
Sewer Name
B JOINT OUTFALL B - UNIT 5C
City
PASADENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
11
Purpose
Routine Assessment
Project
RFIR_WO_896722_TV16034_JUN2021
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
18 in.
Width
57 in.
Upstream MH
B 0439
Downstream MH
B 0438
Dir. of Survey
Downstream
Length Surveyed
387.6 ft.
Total Length
387.6 ft.
Structural Index
3
Structural Quick
3N00
Structural Rating
231
O&M Index
2
O&M Quick
412N
O&M Rating
158
Overall Index
3
Overall Quick
Overall Rating
389
Pipe schematic from manhole B 0439 to B 0438
MH: B 0439MH: B 0438downstream0 ft. AMH - Upstream Manhole, Survey Begins - B 04390 ft. MWL - Water Level, 25 %of cross sectional area0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. MGO - General Observation - COCKROACHES IN MANHOLE2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start2 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start90.3 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"117 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"385.9 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish385.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish385.9 ft. MGO - General Observation - COCKROACHES IN MANHOLE387.6 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK387.6 ft. AMH - Downstream Manhole, Survey Ends - B 0438

Observation photos (3)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES IN MANHOLE

    385.9 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (13)

DistanceCodeObservation
117TBA
0AMHB 0439
385.9SAP
0MWL
387.6MGOCONNECTION AT MH 3 O'CLOCK
0MWM
385.9DAGS
90.3TB
2DAGS
387.6AMHB 0438
0MGOCOCKROACHES IN MANHOLE
2SAP
385.9MGOCOCKROACHES IN MANHOLE

Properties (7)

additional_info
630069062121203
custom_field_three
PROJECTING AGGREGATE
custom_field_two
3
customer
1
datetime
2021-06-22T01:28:30-07:00
documentation
PRO PIPE
is_lateral_inspection
false