Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 11, 2021, 11:55 AM
  • 15 0702_15 0701_06112021_051253.mp4

Date
06/11/2021
W/O
896391
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00602
PipeID
P12594
Time
4:55 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8984
Sewer Name
15 EL MONTE AVENUE TRUNK
City
ARCADIA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
08
Purpose
Routine Assessment
Project
WO_896391_TV15081_JUN2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
15 0702
Downstream MH
15 0701
Dir. of Survey
Downstream
Length Surveyed
403.4 ft.
Total Length
403.4 ft.
Structural Index
3
Structural Quick
3K00
Structural Rating
186
O&M Index
2
O&M Quick
2O00
O&M Rating
160
Overall Index
2
Overall Quick
Overall Rating
346
Pipe schematic from manhole 15 0702 to 15 0701
MH: 15 0702MH: 15 0701downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 15 07020 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK0 ft. MWM - Water Mark, 35 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start24.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"92.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"93.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES95.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"96.7 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start154.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"174 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"185.7 ft. TB - Tap Break-In, at 11 o'clock, -, within 8 inches of joint: YES, 6"221.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"254 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"344.3 ft. TB - Tap Break-In, at 09 o'clock, -, within 8 inches of joint: YES, 6"403.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish403.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish403.4 ft. AMH - Downstream Manhole, Survey Ends - 15 0701403.4 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK403.4 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK

Observation photos (5)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    93.3 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    96.7 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In, at 11 o'clock, -, within 8 inches of joint: YES, 6"

    185.7 ft. - Tap Break-In, at 11 o'clock, -, within 8 inches of joint: YES, 6"

  • Tap Break-In, at 09 o'clock, -, within 8 inches of joint: YES, 6"

    344.3 ft. - Tap Break-In, at 09 o'clock, -, within 8 inches of joint: YES, 6"

Observations (21)

DistanceCodeObservation
174TFC
0MWL
93.3CM
344.3TB
2DAGS
0AMH15 0702
95.3TFC
0MGOCONNECTION AT THE MH 3 OC'LOCK
254TFC
403.3CM
96.7CM
221.9TFC
185.7TB
403.4DAGS
24.3TFC
403.4AMH15 0701
154.8TFC
403.4MGOCONNECTION AT THE MH 9 OC'LOCK
0MWM
403.4MGOCONNECTION AT THE MH 3 OC'LOCK
92.2TFC

Properties (6)

custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2021-06-11T04:55:46-07:00
documentation
PRO PIPE
is_lateral_inspection
false