Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 11, 2021, 09:52 AM
  • 15 0704_15 0703_06112021_025904.mp4

Date
06/11/2021
W/O
896391
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00602
PipeID
P12596
Time
2:52 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8984
Sewer Name
15 EL MONTE AVENUE TRUNK
City
ARCADIA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
08
Purpose
Routine Assessment
Project
WO_896391_TV15081_JUN2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
15 0704
Downstream MH
15 0703
Dir. of Survey
Downstream
Length Surveyed
112.5 ft.
Total Length
112.5 ft.
Structural Index
2
Structural Quick
2200
Structural Rating
4
O&M Index
2
O&M Quick
412C
O&M Rating
48
Overall Index
2
Overall Quick
Overall Rating
52
Pipe schematic from manhole 15 0704 to 15 0703
MH: 15 0704MH: 15 0703downstream0 ft. AMH - Upstream Manhole, Survey Begins - 15 07040 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK0 ft. MWM - Water Mark, 40 %of cross sectional area3.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start25.9 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES55.9 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES112.2 ft. LL - Alignment Left, 50 %112.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish112.5 ft. AMH - Downstream Manhole, Survey Ends - 15 0703 ZOOMED IN

Observation photos (4)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    3.1 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

    25.9 ft. - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

    55.9 ft. - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

  • Alignment Left, 50 %

    112.2 ft. - Alignment Left, 50 %

Observations (10)

DistanceCodeObservation
0AMH15 0704
112.2LL
25.9CL
0MWL
0MGOCONNECTION AT THE MH 3 OC'LOCK
0MWM
112.5AMH15 0703 ZOOMED IN
112.4DAGS
55.9CL
3.1DAGS

Properties (6)

custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2021-06-11T02:52:03-07:00
documentation
PRO PIPE
is_lateral_inspection
false