Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 11, 2021, 07:17 AM
  • 15 0712_15 0711_06112021_002937.mp4

Date
06/11/2021
W/O
896391
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00602
PipeID
P12604
Time
12:17 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8984
Sewer Name
15 EL MONTE AVENUE TRUNK
City
ARCADIA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
08
Purpose
Routine Assessment
Project
WO_896391_TV15081_JUN2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
15 0712
Downstream MH
15 0711
Dir. of Survey
Downstream
Length Surveyed
250.9 ft.
Total Length
250.9 ft.
Structural Index
3
Structural Quick
3I00
Structural Rating
144
O&M Index
2
O&M Quick
322I
O&M Rating
104
Overall Index
3
Overall Quick
Overall Rating
248
Pipe schematic from manhole 15 0712 to 15 0711
MH: 15 0712MH: 15 0711downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 15 07120 ft. MWL - Water Level, 15 %of cross sectional area5.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start9.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start14.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"74.5 ft. RMC - Roots Medium Connection, at 02 o'clock, 10 %, within 8 inches of joint: YES74.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"74.9 ft. RML - Roots Medium Lateral, from 02 to 05 o'clock, 15 %, within 8 inches of joint: YES78.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"142.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"145.8 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 6"250.9 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish250.9 ft. AMH - Downstream Manhole, Survey Ends - 15 0711250.9 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK250.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish

Observation photos (4)

  • Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start

    5.2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    9.1 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Roots Medium Connection, at 02 o'clock, 10 %, within 8 inches of joint: YES

    74.5 ft. - Roots Medium Connection, at 02 o'clock, 10 %, within 8 inches of joint: YES

  • Roots Medium Lateral, from 02 to 05 o'clock, 15 %, within 8 inches of joint: YES

    74.9 ft. - Roots Medium Lateral, from 02 to 05 o'clock, 15 %, within 8 inches of joint: YES

Observations (16)

DistanceCodeObservation
14.5TFC
78.1TF
74.9TF
250.9CM
0MWM
0AMH15 0712
74.5RMC
5.2DAGS
0MWL
9.1CM
145.8TFC
250.9AMH15 0711
250.9MGOCONNECTION AT THE MH 3 OC'LOCK
250.9DAGS
142.6TFC
74.9RML

Properties (6)

custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2021-06-11T00:17:08-07:00
documentation
PRO PIPE
is_lateral_inspection
false