- Date
- 07/02/2021
- W/O
- 896402
- Weather
- Dry
- Operator/Surveyor
- J. BUENROSTRO
- Sewer ID
- Z00043
- PipeID
- P10283
- Time
- 2:07 AM
- Certificate
- U-715-07000770
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K9019
- Sewer Name
- F JOINT OUTFALL F - UNIT 7A
- City
- CERRITOS
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 37
- Purpose
- Routine Assessment
- Project
- RFIR_WO_896402_TV02203_JUN2021
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 60 in.
- Width
- 33 in.
- Upstream MH
- F 0079
- Downstream MH
- F 0078
- Dir. of Survey
- Downstream
- Length Surveyed
- 695.8 ft.
- Total Length
- 695.8 ft.
- Structural Index
- 3
- Structural Quick
- 3100
- Structural Rating
- 3
- O&M Index
- 4
- O&M Quick
- 4100
- O&M Rating
- 4
- Overall Index
- 4
- Overall Quick
- —
- Overall Rating
- 7
Pipe schematic from manhole F 0079 to F 0078 Observation photos (2)

10 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

146.8 ft. - General Observation - MAG COATING