Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 30, 2021, 06:54 AM
  • J 0194_J 0193_06302021_000220.mp4

Date
06/29/2021
W/O
896126
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00055
PipeID
P11433
Time
11:54 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9062
Sewer Name
J JOINT OUTFALL J - UNIT 1C
City
RANCHO PALOS VERDES
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
48
Purpose
Routine Assessment
Project
RFIR_WO_896126_TV05367_JUN2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
27 in.
Width
27 in.
Upstream MH
J 0194
Downstream MH
J 0193
Dir. of Survey
Downstream
Length Surveyed
300.8 ft.
Total Length
300.8 ft.
Structural Index
4
Structural Quick
4B3B
Structural Rating
110
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
110
Pipe schematic from manhole J 0194 to J 0193
MH: J 0194MH: J 0193downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - J 01940 ft. MWM - Water Mark, 25 %of cross sectional area3.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start75.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish75.5 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start158.6 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish300.8 ft. AMH - Downstream Manhole, Survey Ends - J 0193

Observation photos (2)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.6 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    75.5 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
0MWL
75.5CM
300.8AMHJ 0193
158.6FM
0AMHJ 0194
75.5FM
0MWM
3.6CM

Properties (7)

additional_info
630074062921201
custom_field_three
CRACKS/ FRACTURE'S
custom_field_two
3
customer
1
datetime
2021-06-29T23:54:01-07:00
documentation
PROPIPE
is_lateral_inspection
false