- Date
- 06/30/2021
- W/O
- 896148
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00022
- PipeID
- P00468
- Time
- 3:14 AM
- Certificate
- U-508-7069
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K9065
- Sewer Name
- 08 WILMINGTON AVENUE TRUNK
- City
- CARSON
- Loc. details
- Easement/Right of Way
- Location Code
- D
- Use of Sewer
- Sanitary Sewer
- District
- District 08
- Page No.
- 14
- Purpose
- Routine Assessment
- Project
- RFIR_WO_896148_TV08177_JUN2021
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 30 in.
- Width
- 15 in.
- Upstream MH
- 08 0413
- Downstream MH
- 08 0414
- Dir. of Survey
- Upstream
- Length Surveyed
- 81.8 ft.
- Total Length
- 81.8 ft.
- Structural Index
- 3
- Structural Quick
- 3B23
- Structural Rating
- 54
- O&M Index
- 3
- O&M Quick
- 3700
- O&M Rating
- 21
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 75
Pipe schematic from manhole 08 0413 to 08 0414 Observation photos (4)

2.4 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

45.9 ft. - Deposits Settled Other, 15 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Start - SLUDGE

67.8 ft. - Water Level, Sag in pipe, 20 %of cross sectional area, Start

81.8 ft. - Survey Abandoned - CAM BLKD BY SLUDGE 20%