- Date
- 06/24/2021
- W/O
- 896573
- Weather
- Dry
- Operator/Surveyor
- M.MARTINEZ
- Sewer ID
- Z00616
- PipeID
- P12625
- Time
- 1:02 AM
- Certificate
- U-115-06022794
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K8995
- Sewer Name
- 15 MONROVIA OUTFALL TRUNK
- City
- MONROVIA
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 15
- Page No.
- 09
- Purpose
- Routine Assessment
- Project
- WO_896573_TV15131_JUN2021
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 24 in.
- Width
- 24 in.
- Upstream MH
- 15 0732
- Downstream MH
- 15 0731
- Dir. of Survey
- Downstream
- Length Surveyed
- 652.2 ft.
- Total Length
- 652.2 ft.
- Structural Index
- 3
- Structural Quick
- 3221
- Structural Rating
- 8
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 8
Pipe schematic from manhole 15 0732 to 15 0731 Observation photos (5)

2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

2 ft. - General Observation - MAG COAT

13.8 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

22.6 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

149.5 ft. - Tap Break-In, at 03 o'clock, -, within 8 inches of joint: YES, 8"