Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 23, 2021, 04:42 AM
  • 02 1388_02 1387_06222021_231722.mp4

Date
06/22/2021
W/O
896401
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00242
PipeID
P03906
Time
9:42 PM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9001
Sewer Name
02 CLOVERLAWN TRUNK
City
PARAMOUNT
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
31
Purpose
Routine Assessment
Project
WO_896401_TV02041_JUN2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
24 in.
Upstream MH
02 1388
Downstream MH
02 1387
Dir. of Survey
Downstream
Length Surveyed
355 ft.
Total Length
355 ft.
Structural Index
3
Structural Quick
3H22
Structural Rating
143
O&M Index
2
O&M Quick
2M00
O&M Rating
140
Overall Index
2
Overall Quick
Overall Rating
283
Pipe schematic from manhole 02 1388 to 02 1387
MH: 02 1388MH: 02 1387downstream0 ft. AMH - Upstream Manhole, Survey Begins - 02 13880 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MGO - General Observation - COCKROACHES IN MANHOLE0 ft. MWM - Water Mark, 15 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start4.2 ft. FS - Fracture Spiral, from 08 to 10 o'clock, within 8 inches of joint: YES8.3 ft. JOM - Joint Offset Medium45.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"87.9 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES96.1 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 6"121.7 ft. CS - Crack Spiral, from 02 to 05 o'clock, within 8 inches of joint: YES128 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start139.2 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"146.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"196.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"247.4 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 6"297.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"348.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"352.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish352.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish354.9 ft. MGO - General Observation - COCKROACHES IN MANHOLE355 ft. AMH - Downstream Manhole, Survey Ends - 02 1387

Observation photos (7)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Fracture Spiral, from 08 to 10 o'clock, within 8 inches of joint: YES

    4.2 ft. - Fracture Spiral, from 08 to 10 o'clock, within 8 inches of joint: YES

  • Joint Offset Medium

    8.3 ft. - Joint Offset Medium

  • Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

    87.9 ft. - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

  • Crack Spiral, from 02 to 05 o'clock, within 8 inches of joint: YES

    121.7 ft. - Crack Spiral, from 02 to 05 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    128 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES IN MANHOLE

    354.9 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (22)

DistanceCodeObservation
348.1TFC
0AMH02 1388
0MWL
96.1TFC
146.1TFC
0MGOCOCKROACHES IN MANHOLE
297.8TFC
8.3JOM
2DAGS
4.2FS
139.2TBA
121.7CS
0MWM
354.9MGOCOCKROACHES IN MANHOLE
355AMH02 1387
128CM
87.9CL
196.8TFC
247.4TFC
45.7TFC
352.5CM
352.5DAGS

Properties (7)

additional_info
630069062221201
custom_field_three
CRACKS/FRACTURES
custom_field_two
2
customer
1
datetime
2021-06-22T21:42:21-07:00
documentation
PRO PIPE
is_lateral_inspection
false