Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 23, 2021, 06:17 AM
  • 02 1387_02 1386_06222021_233613.mp4

Date
06/22/2021
W/O
896401
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00242
PipeID
P03905
Time
11:17 PM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9001
Sewer Name
02 CLOVERLAWN TRUNK
City
PARAMOUNT
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
31
Purpose
Routine Assessment
Project
WO_896401_TV02041_JUN2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
24 in.
Upstream MH
02 1387
Downstream MH
02 1386
Dir. of Survey
Downstream
Length Surveyed
342.4 ft.
Total Length
342.4 ft.
Structural Index
3
Structural Quick
413L
Structural Rating
202
O&M Index
2
O&M Quick
2M00
O&M Rating
136
Overall Index
3
Overall Quick
Overall Rating
338
Pipe schematic from manhole 02 1387 to 02 1386
MH: 02 1387MH: 02 1386downstream0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. MGO - General Observation - COCKROACHES IN MANHOLE0 ft. AMH - Upstream Manhole, Survey Begins - 02 13870 ft. MWL - Water Level, 10 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start13.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start32.5 ft. TBA - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"41.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"92.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"141.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"195.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"234.6 ft. FS - Fracture Spiral, from 07 to 11 o'clock, within 8 inches of joint: YES330.7 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES340.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish340.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish342.4 ft. AMH - Downstream Manhole, Survey Ends - 02 1386

Observation photos (4)

  • General Observation - COCKROACHES IN MANHOLE

    0 ft. - General Observation - COCKROACHES IN MANHOLE

  • Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

  • Fracture Spiral, from 07 to 11 o'clock, within 8 inches of joint: YES

    234.6 ft. - Fracture Spiral, from 07 to 11 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    330.7 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (16)

DistanceCodeObservation
0MWM
141.5TFC
13.2CM
340.3CM
92.1TFC
234.6FS
330.7FM
0MGOCOCKROACHES IN MANHOLE
0AMH02 1387
195.7TFC
340.3DAGS
41.5TFC
342.4AMH02 1386
2DAGS
0MWL
32.5TBA

Properties (7)

additional_info
630069062221201
custom_field_three
CRACKS/FRACTURES
custom_field_two
2
customer
1
datetime
2021-06-22T23:17:42-07:00
documentation
PRO PIPE
is_lateral_inspection
false