Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 8, 2021, 08:32 AM
  • 32 0084_32 0083_07082021_015940.mp4

Date
07/08/2021
W/O
896103
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00889
PipeID
P19847
Time
1:32 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9025
Sewer Name
32 RYE CANYON TRUNK
City
SANTA CLARITA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 32
Page No.
06
Purpose
Routine Assessment
Project
WO_896103_TV32020_JUN2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
32 0084
Downstream MH
32 0083
Dir. of Survey
Downstream
Length Surveyed
712.6 ft.
Total Length
712.6 ft.
Structural Index
3
Structural Quick
3D25
Structural Rating
79
O&M Index
2
O&M Quick
2\00
O&M Rating
286
Overall Index
2
Overall Quick
Overall Rating
365
Pipe schematic from manhole 32 0084 to 32 0083
MH: 32 0084MH: 32 0083downstream0 ft. AMH - Upstream Manhole, Survey Begins - 32 00840 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. MGO - General Observation - COCKROACHES IN MANHOLE0 ft. MWM - Water Mark, 15 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start11.4 ft. CL - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES49.1 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES49.4 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"49.4 ft. MGO - General Observation - RUN LIST STATES RCP.168.1 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES340.6 ft. TBI - Tap Break-In Intruding, at 02 o'clock, -, #v, within 8 inches of joint: NO, 6", 1"424.5 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6", 6"579.9 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES583.3 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"586.3 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES594.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start711 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish711 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish712.6 ft. AMH - Downstream Manhole, Survey Ends - 32 0083712.6 ft. MGO - General Observation - COCKROACHES IN MANHOLE

Observation photos (11)

  • General Observation - COCKROACHES IN MANHOLE

    0 ft. - General Observation - COCKROACHES IN MANHOLE

  • Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

  • Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES

    11.4 ft. - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

    49.1 ft. - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

  • General Observation - RUN LIST STATES RCP.

    49.4 ft. - General Observation - RUN LIST STATES RCP.

  • Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

    168.1 ft. - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

  • Tap Break-In Intruding, at 02 o'clock, -, #v, within 8 inches of joint: NO, 6", 1"

    340.6 ft. - Tap Break-In Intruding, at 02 o'clock, -, #v, within 8 inches of joint: NO, 6", 1"

  • Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

    579.9 ft. - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

    586.3 ft. - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    594.2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES IN MANHOLE

    712.6 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (21)

DistanceCodeObservation
424.5TB
168.1CL
712.6AMH32 0083
583.3TBA
49.1CL
0AMH32 0084
0MWL
712.6MGOCOCKROACHES IN MANHOLE
2DAGS
49.4TFA
49.4MGORUN LIST STATES RCP.
340.6TBI
11.4CL
594.2CM
579.9CL
0MGOCONNECTION AT MH 9 O'CLOCK
0MGOCOCKROACHES IN MANHOLE
711DAGS
0MWM
711CM
586.3CL

Properties (7)

additional_info
630069070721202
custom_field_three
MULTIPLE CRACKS
custom_field_two
2
customer
1
datetime
2021-07-08T01:32:00-07:00
documentation
PRO PIPE
is_lateral_inspection
false