- Date
- 07/12/2021
- W/O
- 001673
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00896
- PipeID
- P20958
- Time
- 3:41 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H1869
- Sewer Name
- 02 ARTHUR AVENUE TRUNK
- City
- PARAMOUNT BLVD
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 31
- Purpose
- Capital Improvement Program Assesment
- Project
- 20210712MDM_ARTHUR_AVENUE_TRUNK
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 24 in.
- Upstream MH
- 02 2328
- Downstream MH
- 02 2327
- Dir. of Survey
- Downstream
- Length Surveyed
- 299.6 ft.
- Total Length
- 299.6 ft.
- Structural Index
- 2
- Structural Quick
- 2200
- Structural Rating
- 4
- O&M Index
- 3
- O&M Quick
- 4122
- O&M Rating
- 8
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 12
Pipe schematic from manhole 02 2328 to 02 2327 Observation photos (3)

46.5 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

77.6 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SLIGHT BLISTERING OUTER SURFACE

265 ft. - Water Level, 40 %of cross sectional area