Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 14, 2021, 08:30 AM
  • 01 0266B_01 0266A_06142021_013852.mp4

Date
06/14/2021
W/O
896354
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00218
PipeID
P01314
Time
1:30 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8897
Sewer Name
01 SOUTH PARK AVENUE TRUNK
City
LOS ANGELES
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
09
Purpose
Routine Assessment
Project
RFIR_WO_896354_TV01204_JUN2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
18 in.
Upstream MH
01 0266B
Downstream MH
01 0266A
Dir. of Survey
Downstream
Length Surveyed
149.1 ft.
Total Length
149.1 ft.
Structural Index
3
Structural Quick
4E3E
Structural Rating
261
O&M Index
2
O&M Quick
2E00
O&M Rating
58
Overall Index
3
Overall Quick
Overall Rating
319
Pipe schematic from manhole 01 0266B to 01 0266A
MH: 01 0266BMH: 01 0266Adownstream0 ft. MGO - General Observation - ROACHES @ MH0 ft. AMH - Upstream Manhole, Survey Begins - 01 0266B0 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/ACTIVE0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2.5 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start25.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"55.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"88 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"114.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN126.9 ft. TS - Tap Saddle, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN147 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish147 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish147 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish149.1 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish149.1 ft. AMH - Downstream Manhole, Survey Ends - 01 0266A149.1 ft. MGO - General Observation - ROACHES @ MH149.1 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/ACTIVE

Observation photos (2)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.5 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Saddle, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN

    126.9 ft. - Tap Saddle, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN

Observations (21)

DistanceCodeObservation
55.7TFC
2SSS
147DAGS
0MGOROACHES @ MH
149.1FM
0AMH01 0266B
0MGOCONN @ MH 3 O'CLOCK/ACTIVE
147SSS
126.9TSOPEN
147CM
2CM
88TFC
0MWL
149.1AMH01 0266A
2DAGS
2.5FM
149.1MGOROACHES @ MH
25.8TFC
0MWM
149.1MGOCONN @ MH 9 O'CLOCK/ACTIVE
114.7TFOPEN

Properties (7)

additional_info
630074061421001
custom_field_three
MULTIPLE FRACTURES
custom_field_two
2
customer
1
datetime
2021-06-14T01:30:39-07:00
documentation
PROPIPE
is_lateral_inspection
false