Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 14, 2021, 09:01 AM
  • 01 0265_01 0264_06142021_021420.mp4

Date
06/14/2021
W/O
896354
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00218
PipeID
P01311
Time
2:01 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8897
Sewer Name
01 SOUTH PARK AVENUE TRUNK
City
LOS ANGELES
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
09
Purpose
Routine Assessment
Project
RFIR_WO_896354_TV01204_JUN2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
18 in.
Upstream MH
01 0265
Downstream MH
01 0264
Dir. of Survey
Downstream
Length Surveyed
337.4 ft.
Total Length
337.4 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2M00
O&M Rating
136
Overall Index
2
Overall Quick
Overall Rating
136
Pipe schematic from manhole 01 0265 to 01 0264
MH: 01 0265MH: 01 0264downstream0 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/ACTIVE0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 01 02650 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/CAPPED0 ft. MWM - Water Mark, 20 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2.4 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 07 to 08 o'clock, , within 8 inches of joint: YES3.8 ft. MGO - General Observation - PIPE IS LINED151.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN179 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN242.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN335 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish337.4 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/ACTIVE337.4 ft. AMH - Downstream Manhole, Survey Ends - 01 0264

Observation photos (1)

  • Deposits Attached Grease, 10 %of cross sectional area, from 07 to 08 o'clock,  , within 8 inches of joint: YES

    2.4 ft. - Deposits Attached Grease, 10 %of cross sectional area, from 07 to 08 o'clock, , within 8 inches of joint: YES

Observations (14)

DistanceCodeObservation
242.6TFOPEN
179TFOPEN
151.8TFOPEN
335DAGS
0MGOCONN @ MH 3 O'CLOCK/ACTIVE
0MWL
2.4DAGS
337.4MGOCONN @ MH 3 O'CLOCK/ACTIVE
0AMH01 0265
2DAGS
0MGOCONN @ MH 9 O'CLOCK/CAPPED
0MWM
3.8MGOPIPE IS LINED
337.4AMH01 0264

Properties (7)

additional_info
630074061421001
custom_field_three
RFIR NO SEVERE DEFECTS/PIPE IS LINED
custom_field_two
4
customer
1
datetime
2021-06-14T02:01:07-07:00
documentation
PROPIPE
is_lateral_inspection
false