- Date
- 06/02/2021
- W/O
- 896122
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00279
- PipeID
- P03530
- Time
- 3:32 AM
- Certificate
- U-0720-70309212
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K8934
- Sewer Name
- 02 MONTEBELLO TRUNK
- City
- BELL GARDENS
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 23
- Purpose
- Routine Assessment
- Project
- RFIR_WO_896122_TV02320_JUN2021
- Sewer Type
- Gravity
- Material
- NRCP
- Shape
- Circular
- Height
- 21 in.
- Width
- 33 in.
- Upstream MH
- 02 0960
- Downstream MH
- 02 1400
- Dir. of Survey
- Upstream
- Length Surveyed
- 86.5 ft.
- Total Length
- 86.5 ft.
- Structural Index
- 3
- Structural Quick
- 3B2B
- Structural Rating
- 80
- O&M Index
- 2
- O&M Quick
- 2B00
- O&M Rating
- 34
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 114
Pipe schematic from manhole 02 0960 to 02 1400 Observation photos (4)

2 ft. - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start - DEBRIS

4.3 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

4.3 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

86.5 ft. - General Observation - ROACHES @ MH