Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 2, 2021, 08:54 AM
  • 02 0959_02 0958_06022021_023347.mp4

Date
06/02/2021
W/O
896122
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00279
PipeID
P03528
Time
1:54 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8934
Sewer Name
02 MONTEBELLO TRUNK
City
BELL GARDENS
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
23
Purpose
Routine Assessment
Project
RFIR_WO_896122_TV02320_JUN2021
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
21 in.
Width
33 in.
Upstream MH
02 0958
Downstream MH
02 0959
Dir. of Survey
Upstream
Length Surveyed
350.9 ft.
Total Length
350.9 ft.
Structural Index
2
Structural Quick
2M00
Structural Rating
138
O&M Index
2
O&M Quick
2M00
O&M Rating
138
Overall Index
2
Overall Quick
Overall Rating
276
Pipe schematic from manhole 02 0958 to 02 0959
MH: 02 0958MH: 02 0959upstream0 ft. AMH - Upstream Manhole, Survey Ends - 02 09591.4 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish2.9 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish348.9 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start348.9 ft. MGO - General Observation - 95% MAG COAT348.9 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start - DEBRIS350.9 ft. MWL - Water Level, 10 %of cross sectional area350.9 ft. AMH - Downstream Manhole, Survey Begins - 02 0958350.9 ft. MWM - Water Mark, 15 %of cross sectional area

Observation photos (2)

  • General Observation - 95% MAG COAT

    2 ft. - General Observation - 95% MAG COAT

  • Deposits Settled Other,  10 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start - DEBRIS

    2 ft. - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start - DEBRIS

Observations (9)

DistanceCodeObservation
0MWL
2SSS
0AMH02 0958
2MGO95% MAG COAT
348SSS
350.9AMH02 0959
0MWM
349.5DSZ
2DSZDEBRIS

Properties (7)

additional_info
630069060121203
custom_field_three
MAG COATING
custom_field_two
4
customer
1
datetime
2021-06-02T01:54:11-07:00
documentation
PRO PIPE
is_lateral_inspection
false