- Date
- 06/14/2021
- W/O
- 896122
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00279
- PipeID
- P03521
- Time
- 11:47 PM
- Certificate
- U-0720-70309212
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K8938
- Sewer Name
- 02 MONTEBELLO TRUNK
- City
- BELL GARDENS
- Loc. details
- Easement/Right of Way
- Location Code
- D
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 23
- Purpose
- Routine Assessment
- Project
- RFIR_WO_896122_TV02320_JUN2021
- Sewer Type
- Gravity
- Material
- NRCP
- Shape
- Circular
- Height
- 21 in.
- Width
- 27 in.
- Upstream MH
- 02 0952
- Downstream MH
- 02 0951
- Dir. of Survey
- Downstream
- Length Surveyed
- 345.6 ft.
- Total Length
- 345.6 ft.
- Structural Index
- 3
- Structural Quick
- 3M2M
- Structural Rating
- 340
- O&M Index
- 2
- O&M Quick
- 2Z00
- O&M Rating
- 274
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 614
Pipe schematic from manhole 02 0952 to 02 0951 Observation photos (5)

0 ft. - General Observation - ROACHES @ MH

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

2 ft. - General Observation - 70% MAG COAT

5.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

345.6 ft. - General Observation - ROACHES @ MH