- Date
- 05/28/2021
- W/O
- 890827
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00706
- PipeID
- P14561
- Time
- 1:35 AM
- Certificate
- U-0720-70309212
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K8930
- Sewer Name
- 18 SO WHITTIER OUTFALL TR, SECTS 1,2,3,&4
- City
- SANTA FE SPRINGS
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 18
- Page No.
- 31
- Purpose
- Routine Assessment
- Project
- RFIR_WO_890827_TV18104_MAY2021
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 42 in.
- Width
- 42 in.
- Upstream MH
- 18 0711
- Downstream MH
- 18 0710
- Dir. of Survey
- Downstream
- Length Surveyed
- 256.5 ft.
- Total Length
- 256.5 ft.
- Structural Index
- 3
- Structural Quick
- 3I2I
- Structural Rating
- 250
- O&M Index
- 2
- O&M Quick
- 2P00
- O&M Rating
- 168
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 418
Pipe schematic from manhole 18 0711 to 18 0710 Observation photos (3)

2 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

253.9 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish - Visible Aggregate