- Date
- 06/01/2021
- W/O
- 890827
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00706
- PipeID
- P14547
- Time
- 9:57 PM
- Certificate
- U-508-7069
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K8884
- Sewer Name
- 18 SO WHITTIER OUTFALL TR, SECTS 1,2,3,&4
- City
- SANTA FE SPRINGS
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 18
- Page No.
- 34
- Purpose
- Routine Assessment
- Project
- RFIR_WO_890827_TV18104_MAY2021
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 48 in.
- Width
- 48 in.
- Upstream MH
- 18 0697
- Downstream MH
- 18 0696
- Dir. of Survey
- Downstream
- Length Surveyed
- 468.1 ft.
- Total Length
- 468.1 ft.
- Structural Index
- 3
- Structural Quick
- 3100
- Structural Rating
- 3
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 3
Pipe schematic from manhole 18 0697 to 18 0696 Observation photos (2)

2.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

85.7 ft. - Tap Factory Made, at 08 o'clock, -, within 8 inches of joint: NO, 6" - Connection at 7 o'clock