Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 25, 2021, 06:11 AM
  • 18 0725_18 0724A_05242021_231517.mp4

Date
05/24/2021
W/O
890827
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00706
PipeID
P23804
Time
11:11 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8877
Sewer Name
18 SO WHITTIER OUTFALL TR, SECTS 1,2,3,&4
City
SANTA FE SPRINGS
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
31
Purpose
Routine Assessment
Project
RFIR_WO_890827_TV18104_MAY2021
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
36 in.
Width
36 in.
Upstream MH
18 0725
Downstream MH
18 0724A
Dir. of Survey
Downstream
Length Surveyed
33.9 ft.
Total Length
33.9 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole 18 0725 to 18 0724A
MH: 18 0725MH: 18 0724Adownstream0 ft. AMH - Upstream Manhole, Survey Begins - 18 07250 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area2.6 ft. MGO - General Observation - MAG COAT2.9 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start33.9 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish33.9 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK33.9 ft. AMH - Downstream Manhole, Survey Ends - 18 0724A

Observation photos (1)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.9 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
33.9SAV
0AMH18 0725
0MWL
2.6MGOMAG COAT
33.9MGOCONNECTION AT MH 3 O'CLOCK
0MWM
33.9AMH18 0724A
2.9SAV

Properties (7)

additional_info
630138052421201
custom_field_three
AGGREGATE VISIBLE
custom_field_two
3
customer
1
datetime
2021-05-24T23:11:35-07:00
documentation
PROPIPE
is_lateral_inspection
false