Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 27, 2021, 09:05 AM
  • 18 0781_18 0780_05272021_021733.mp4

Date
05/27/2021
W/O
890827
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00706
PipeID
P14639
Time
2:05 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8882
Sewer Name
18 SO WHITTIER OUTFALL TR, SECTS 1,2,3,&4
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
20
Purpose
Routine Assessment
Project
RFIR_WO_890827_TV18104_MAY2021
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
30 in.
Width
30 in.
Upstream MH
18 0780
Downstream MH
18 0781
Dir. of Survey
Upstream
Length Surveyed
155.5 ft.
Total Length
155.5 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole 18 0780 to 18 0781
MH: 18 0780MH: 18 0781upstream0 ft. AMH - Upstream Manhole, Survey Ends - 18 07810 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish153 ft. MGO - General Observation - MAG COAT153 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start155.5 ft. AMH - Downstream Manhole, Survey Begins - 18 0780155.5 ft. MWM - Water Mark, 30 %of cross sectional area155.5 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK155.5 ft. MWL - Water Level, 15 %of cross sectional area

Observation photos (1)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.5 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
0AMH18 0780
155.5AMH18 0781
2.5MGOMAG COAT
2.5SAV
0MWM
0MGOCONNECTION AT MH 9 O'CLOCK
0MWL
155.5SAV

Properties (7)

additional_info
630138052621201
custom_field_three
AGGREGATE VISIBLE
custom_field_two
3
customer
1
datetime
2021-05-27T02:05:24-07:00
documentation
PROPIPE
is_lateral_inspection
false