Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 7, 2021, 10:45 AM
  • 18 0863_18 0693_06072021_035058.mp4

Date
06/07/2021
W/O
890827
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00706
PipeID
P14543
Time
3:45 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8885
Sewer Name
18 SO WHITTIER OUTFALL TR, SECTS 1,2,3,&4
City
NORWALK
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
34
Purpose
Routine Assessment
Project
RFIR_WO_890827_TV18104_MAY2021
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
48 in.
Width
48 in.
Upstream MH
18 0863
Downstream MH
18 0693
Dir. of Survey
Downstream
Length Surveyed
9.3 ft.
Total Length
9.3 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole 18 0863 to 18 0693
MH: 18 0863MH: 18 0693downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK0 ft. AMH - Upstream Manhole, Survey Begins - 18 08630 ft. MWM - Water Mark, 30 %of cross sectional area4.1 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES4.1 ft. MGO - General Observation - MAG COAT9.2 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK CAPPED9.3 ft. AMH - Downstream Manhole, Survey Ends - 18 0693

Observation photos (1)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES

    4.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (8)

DistanceCodeObservation
0MWL
0MGOCONNECTION AT THE MH 3 OC'LOCK
0AMH18 0863
4.1SAP
9.2MGOCONNECTION AT THE MH 3 OC'LOCK CAPPED
4.1MGOMAG COAT
9.3AMH18 0693
0MWM

Properties (7)

additional_info
630074060721001
custom_field_three
AGGREGATE PROJECTING
custom_field_two
2
customer
1
datetime
2021-06-07T03:45:00-07:00
documentation
PROPIPE
is_lateral_inspection
false