Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 30, 2021, 08:45 AM
  • 18 0863_18 0862_6302021_031819.mp4

Date
06/30/2021
W/O
0890824
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00709
PipeID
P14715
Time
1:45 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1859
Sewer Name
18 SO WHITTIER OUTFALL RLF TR, SECTS 1,2A,2B,2C,&3
City
BELLFLOWER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
34
Purpose
Capital Improvement Program Assesment
Project
20210630MDM_SO_WHITTIER_OUTFALL_RLF_TR_SECTS_1_2A_2C_3
Material
Reinforced Concrete Pipe
Shape
Circular
Height
51 in.
Upstream MH
18 0863
Downstream MH
18 0862
Dir. of Survey
Downstream
Length Surveyed
1010.9 ft.
Total Length
1010.9 ft.
Structural Index
3
Structural Quick
4623
Structural Rating
30
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
30
Pipe schematic from manhole 18 0863 to 18 0862
MH: 18 0863MH: 18 0862downstream0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 3:15AM0 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active LARGE INCOMING2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE2 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG9 ft. MGO - General Observation - 51" RCP23.7 ft. SAM - Surface Aggregate Missing, from 03 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG31.5 ft. SAM - Surface Aggregate Missing, from 08 to 09 o'clock, within 8 inches of joint: NO - SEVERE AGG62.5 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - PEELING BLISTERING CONCRETE95.8 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG203.2 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG376.6 ft. MGP - General Photograph466.8 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - PEELING CONCRETE754.3 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG774.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open1010.3 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - BLISTERING PEELING CONCRETE1010.3 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG1010.9 ft. AMH - Downstream Manhole, Survey Ends - 4:25AM

Observation photos (11)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

  • Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

    2 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

  • General Observation - 51" RCP

    9 ft. - General Observation - 51" RCP

  • Surface Aggregate Missing, from 03 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG

    23.7 ft. - Surface Aggregate Missing, from 03 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG

  • Surface Aggregate Missing, from 08 to 09 o'clock, within 8 inches of joint: NO - SEVERE AGG

    31.5 ft. - Surface Aggregate Missing, from 08 to 09 o'clock, within 8 inches of joint: NO - SEVERE AGG

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - PEELING BLISTERING CONCRETE

    62.5 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - PEELING BLISTERING CONCRETE

  • Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG

    95.8 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG

  • Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG

    203.2 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG

  • General Photograph

    376.6 ft. - General Photograph

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - PEELING CONCRETE

    466.8 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - PEELING CONCRETE

  • Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG

    754.3 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG

Observations (19)

DistanceCodeObservation
203.2SAMSEVERE AGG
31.5SAMSEVERE AGG
1010.3SSSBLISTERING PEELING CONCRETE
2SSSBLISTERING PEELING CONCRETE
376.6MGP
1010.3SAMSEVERE AGG
0MWM
9MGO51" RCP
62.5SSSPEELING BLISTERING CONCRETE
95.8SAMSEVERE AGG
0MWL
754.3SAMSEVERE AGG
23.7SAMSEVERE AGG
2SAMSEVERE AGG
0AMH3:15AM
1010.9AMH4:25AM
466.8SSSPEELING CONCRETE
0MGOConn. @ Mh, 3 O' Clock. Active LARGE INCOMING
774.2TFOpen

Properties (6)

custom_field_three
SEVERE AGG MISSING
custom_field_two
2
customer
LACSD
datetime
2021-06-30T01:45:22-07:00
documentation
MARTIN,REVELES,OLIVER 111,RAMIREZ
is_lateral_inspection
false