Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 24, 2021, 05:18 AM
  • 18 0251_18 0250_06232021_222332.mp4

Date
06/23/2021
W/O
896153
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00672
PipeID
P14079
Time
10:18 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9054
Sewer Name
18 BROADWAY TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
13
Purpose
Routine Assessment
Project
WO_896153_TV18003_JUN2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
18 0251
Downstream MH
18 0250
Dir. of Survey
Downstream
Length Surveyed
105.5 ft.
Total Length
105.5 ft.
Structural Index
2
Structural Quick
3C2D
Structural Rating
110
O&M Index
2
O&M Quick
2C00
O&M Rating
40
Overall Index
2
Overall Quick
Overall Rating
150
Pipe schematic from manhole 18 0251 to 18 0250
MH: 18 0251MH: 18 0250downstream0 ft. AMH - Upstream Manhole, Survey Begins - 18 02510 ft. MWL - Water Level, 25 %of cross sectional area0.1 ft. MWM - Water Mark, 30 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start5.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start24.6 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"50 ft. MWM - Water Mark, 35 %of cross sectional area78 ft. MWLS - Water Level, Sag in pipe, 10 %of cross sectional area, Start100.9 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"103 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish103 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish103 ft. MWLS - Water Level, Sag in pipe, 10 %of cross sectional area, Finish105.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish105.5 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/ACTIVE105.5 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/ACTIVE105.5 ft. AMH - Downstream Manhole, Survey Ends - 18 0250

Observation photos (1)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    5.2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (17)

DistanceCodeObservation
24.6TFC
78MWLS
0AMH18 0251
2DAGS
2SSS
50MWM
105.5CM
103DAGS
100.9TFC
103SSS
103MWLS
105.5MGOCONN @ MH 9 O'CLOCK/ACTIVE
105.5MGOCONN @ MH 3 O'CLOCK/ACTIVE
105.5AMH18 0250
5.2CM
0MWL
0.1MWM

Properties (7)

additional_info
630074062321201
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2021-06-23T22:18:06-07:00
documentation
PROPIPE
is_lateral_inspection
false