Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 24, 2021, 08:47 AM
  • 18 0265_18 0264_06242021_015822.mp4

Date
06/24/2021
W/O
896153
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00672
PipeID
P14093
Time
1:47 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9054
Sewer Name
18 BROADWAY TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
13
Purpose
Routine Assessment
Project
WO_896153_TV18003_JUN2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
18 0264
Downstream MH
18 0265
Dir. of Survey
Upstream
Length Surveyed
327 ft.
Total Length
327 ft.
Structural Index
2
Structural Quick
3K2L
Structural Rating
309
O&M Index
2
O&M Quick
2L00
O&M Rating
130
Overall Index
2
Overall Quick
Overall Rating
439
Pipe schematic from manhole 18 0264 to 18 0265
MH: 18 0264MH: 18 0265upstream0 ft. MGO - General Observation - ROACHES @ MH0 ft. AMH - Upstream Manhole, Survey Ends - 18 02650 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish295.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start314.9 ft. CL - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES325 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start325 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start327 ft. MWL - Water Level, 25 %of cross sectional area327 ft. MWM - Water Mark, 30 %of cross sectional area327 ft. MGO - General Observation - ROACHES @ MH327 ft. AMH - Downstream Manhole, Survey Begins - 18 0264

Observation photos (2)

  • Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES

    12.1 ft. - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    31.9 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (13)

DistanceCodeObservation
0MWL
325DAGS
31.9CM
327MGOROACHES @ MH
2DAGS
327AMH18 0265
327CM
0MWM
0MGOROACHES @ MH
0AMH18 0264
2SSS
12.1CL
325SSS

Properties (7)

additional_info
630074062321201
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2021-06-24T01:47:51-07:00
documentation
PROPIPE
is_lateral_inspection
false