Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 2, 2021, 05:27 AM
  • 02 0032A_02 0032_06012021_223631.mp4

Date
06/01/2021
W/O
896218
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00234
PipeID
P03064
Time
10:27 PM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8933
Sewer Name
02 ARTESIA EXTENSION TRUNK
City
CERRITOS
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
39
Purpose
Routine Assessment
Project
RFIR_WO_896218_TV02341_JUN2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
8 in.
Upstream MH
02 0032A
Downstream MH
02 0032
Dir. of Survey
Downstream
Length Surveyed
182.7 ft.
Total Length
182.7 ft.
Structural Index
3
Structural Quick
4E3F
Structural Rating
298
O&M Index
2
O&M Quick
412F
O&M Rating
74
Overall Index
3
Overall Quick
Overall Rating
372
Pipe schematic from manhole 02 0032A to 02 0032
MH: 02 0032AMH: 02 0032downstream0 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/ACTIVE0 ft. MWL - Water Level, 30 %of cross sectional area0 ft. MGO - General Observation - ROACHES @ MH0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 0032A2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start5.9 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start - DEBRIS29.7 ft. RPZ - Repair Other, within 8 inches of joint: YES29.7 ft. JSL - Joint Separated Large35.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"35.7 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start180 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish180 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish180.6 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish180.6 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish182.7 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/UNKNOWN182.7 ft. MGO - General Observation - ROACHES @ MH182.7 ft. AMH - Downstream Manhole, Survey Ends - 02 0032

Observation photos (5)

  • General Observation - ROACHES @ MH

    0 ft. - General Observation - ROACHES @ MH

  • Repair Other, within 8 inches of joint: YES

    29.7 ft. - Repair Other, within 8 inches of joint: YES

  • Joint Separated Large

    29.7 ft. - Joint Separated Large

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    35.7 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • General Observation - ROACHES @ MH

    182.7 ft. - General Observation - ROACHES @ MH

Observations (19)

DistanceCodeObservation
180SSS
0MGOCONN @ MH 3 O'CLOCK/ACTIVE
0MWL
35.7TFC
2CM
182.7MGOCONN @ MH 9 O'CLOCK/UNKNOWN
182.7MGOROACHES @ MH
35.7FM
0MGOROACHES @ MH
182.7AMH02 0032
5.9DSZDEBRIS
29.7RPZ
0MWM
2SSS
0AMH02 0032A
180.6FM
29.7JSL
180.6DSZ
180CM

Properties (7)

additional_info
630069060121202
custom_field_three
FRACTURES
custom_field_two
2
customer
1
datetime
2021-06-01T22:27:57-07:00
documentation
PRO PIPE
is_lateral_inspection
false