Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 2, 2021, 05:36 AM
  • 02 0032_02 0031_06012021_224701.mp4

Date
06/01/2021
W/O
896218
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00234
PipeID
P03063
Time
10:36 PM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8933
Sewer Name
02 ARTESIA EXTENSION TRUNK
City
CERRITOS
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
39
Purpose
Routine Assessment
Project
RFIR_WO_896218_TV02341_JUN2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
10 in.
Upstream MH
02 0032
Downstream MH
02 0031
Dir. of Survey
Downstream
Length Surveyed
328.4 ft.
Total Length
328.4 ft.
Structural Index
4
Structural Quick
4K00
Structural Rating
248
O&M Index
2
O&M Quick
2G00
O&M Rating
84
Overall Index
3
Overall Quick
Overall Rating
332
Pipe schematic from manhole 02 0032 to 02 0031
MH: 02 0032MH: 02 0031downstream0 ft. MWL - Water Level, 25 %of cross sectional area0 ft. MGO - General Observation - ROACHES @ MH0 ft. AMH - Upstream Manhole, Survey Begins - 02 00320 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/UNKNOWN15.5 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start116.1 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 09 to 03 o'clock, , within 8 inches of joint: YES, Start174.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"176.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"266 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"268.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"326.7 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 09 to 03 o'clock, , within 8 inches of joint: YES, Finish326.7 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish328.4 ft. AMH - Downstream Manhole, Survey Ends - 02 0031328.4 ft. MGO - General Observation - ROACHES @ MH

Observation photos (3)

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    15.5 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Encrustation, 5 %of cross sectional area, from 09 to 03 o'clock,  , within 8 inches of joint: YES, Start

    116.1 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 09 to 03 o'clock, , within 8 inches of joint: YES, Start

  • General Observation - ROACHES @ MH

    328.4 ft. - General Observation - ROACHES @ MH

Observations (15)

DistanceCodeObservation
266TFC
116.1DAE
326.7DAE
328.4AMH02 0031
174.3TFC
326.7FM
268.1TFC
0MWL
0MGOROACHES @ MH
0AMH02 0032
0MWM
176.9TFC
328.4MGOROACHES @ MH
15.5FM
0MGOCONN @ MH 9 O'CLOCK/UNKNOWN

Properties (7)

additional_info
630069060121202
custom_field_three
MULTIPLE CRACKCS
custom_field_two
3
customer
1
datetime
2021-06-01T22:36:51-07:00
documentation
PRO PIPE
is_lateral_inspection
false