Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 24, 2021, 06:40 AM
  • B 0408_B 0407_06242021_000029.mp4

Date
06/23/2021
W/O
896574
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00092
PipeID
P08920
Time
11:40 PM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8994
Sewer Name
B JOINT OUTFALL B - UNIT 5B
City
ARCADIA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
07
Purpose
Routine Assessment
Project
RFIR_WO_896574_TV15053_JUN2021
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
21 in.
Width
57 in.
Upstream MH
B 0408
Downstream MH
B 0407
Dir. of Survey
Downstream
Length Surveyed
245.9 ft.
Total Length
245.9 ft.
Structural Index
2
Structural Quick
2100
Structural Rating
2
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole B 0408 to B 0407
MH: B 0408MH: B 0407downstream0 ft. MWM - Water Mark, 45 %of cross sectional area0 ft. MWL - Water Level, 40 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - B 04082 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. MGO - General Observation - MAG COAT95.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 8" - debris103.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"159.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 8" - DEBIRS223.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 8" - DEBRIS/POSSIBLE CAP243.3 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish245.9 ft. AMH - Downstream Manhole, Survey Ends - B 0407245.9 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 3 O'CLOCK

Observation photos (4)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Observation - MAG COAT

    2 ft. - General Observation - MAG COAT

  • Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 8" - DEBIRS

    159.9 ft. - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 8" - DEBIRS

  • Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 8" - DEBRIS/POSSIBLE CAP

    223.7 ft. - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 8" - DEBRIS/POSSIBLE CAP

Observations (12)

DistanceCodeObservation
223.7TFDEBRIS/POSSIBLE CAP
0MWM
245.9AMHB 0407
103.6TFC
159.9TFDEBIRS
0MWL
2SSS
2MGOMAG COAT
0AMHB 0408
245.9MGOACTIVE CONNECTION AT MH 3 O'CLOCK
243.3SSS
95.4TFdebris

Properties (6)

custom_field_three
MAG COAT, SPALLING, FAST FLOW
custom_field_two
3
customer
1
datetime
2021-06-23T23:40:46-07:00
documentation
PRO PIPE
is_lateral_inspection
false