Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 23, 2021, 10:12 AM
  • 15 0673_15 0672_06232021_032406.mp4

Date
06/23/2021
W/O
896357
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00602
PipeID
P12565
Time
3:12 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8992
Sewer Name
15 EL MONTE AVENUE TRUNK
City
TEMPLE CITY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
11
Purpose
Routine Assessment
Project
RFIR_WO_896357_TV15208_JUN2021
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
15 0673
Downstream MH
15 0672
Dir. of Survey
Downstream
Length Surveyed
271.3 ft.
Total Length
271.3 ft.
Structural Index
3
Structural Quick
3121
Structural Rating
5
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
5
Pipe schematic from manhole 15 0673 to 15 0672
MH: 15 0673MH: 15 0672downstream0 ft. AMH - Upstream Manhole, Survey Begins - 15 06730 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 9 O'CLOCK0 ft. MWM - Water Mark, 35 %of cross sectional area2.6 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.6 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start148.4 ft. MGO - General Observation - MAG COAT158.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"170.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"224.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"268.9 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish268.9 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish269.4 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK CAPPED271.3 ft. AMH - Downstream Manhole, Survey Ends - 15 0672271.3 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 3 O'CLOCK

Observation photos (3)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.6 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.6 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Observation - MAG COAT

    148.4 ft. - General Observation - MAG COAT

Observations (15)

DistanceCodeObservation
170.6TFC
0AMH15 0673
0MWL
268.9SSS
2.6SAV
268.9SAV
224.4TFC
271.3AMH15 0672
0MGOACTIVE CONNECTION AT MH 9 O'CLOCK
158.3TFC
271.3MGOACTIVE CONNECTION AT MH 3 O'CLOCK
0MWM
148.4MGOMAG COAT
2.6SSS
269.4MGOCONNECTION AT MH 3 O'CLOCK CAPPED

Properties (6)

custom_field_three
AGGREGATE VISIBLE, SPALLING
custom_field_two
3
customer
1
datetime
2021-06-23T03:12:35-07:00
documentation
PRO PIPE
is_lateral_inspection
false