- Date
- 05/17/2021
- W/O
- 890890
- Weather
- Dry
- Operator/Surveyor
- M.MARTINEZ
- Sewer ID
- Z00009
- PipeID
- P00235
- Time
- 10:24 PM
- Certificate
- U-115-06022794
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K8960
- Sewer Name
- 08 GRACE STREET TRUNK, SECTION 1
- City
- CARSON
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 08
- Page No.
- 10
- Purpose
- Routine Assessment
- Project
- RFIR_WO_890890_TV08020_MAY2021
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 12 in.
- Width
- 18 in.
- Upstream MH
- 08 0177
- Downstream MH
- 08 0176
- Dir. of Survey
- Downstream
- Length Surveyed
- 131.5 ft.
- Total Length
- 131.5 ft.
- Structural Index
- 2
- Structural Quick
- 3126
- Structural Rating
- 15
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 15
Pipe schematic from manhole 08 0177 to 08 0176 Observation photos (7)

10.2 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

19.7 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

49 ft. - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES

52 ft. - Crack Spiral, from 11 to 12 o'clock, within 8 inches of joint: YES

93.7 ft. - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

99.5 ft. - Crack Spiral, from 08 to 12 o'clock, within 8 inches of joint: YES

108.5 ft. - Crack Spiral, from 09 to 11 o'clock, within 8 inches of joint: YES