Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 18, 2021, 06:04 AM
  • 08 0174_08 0173_05172021_232445.mp4

Date
05/17/2021
W/O
890890
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00009
PipeID
P00232
Time
11:04 PM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8960
Sewer Name
08 GRACE STREET TRUNK, SECTION 1
City
CARSON
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
10
Purpose
Routine Assessment
Project
RFIR_WO_890890_TV08020_MAY2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
18 in.
Upstream MH
08 0174
Downstream MH
08 0173
Dir. of Survey
Downstream
Length Surveyed
226 ft.
Total Length
226 ft.
Structural Index
2
Structural Quick
3425
Structural Rating
22
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
22
Pipe schematic from manhole 08 0174 to 08 0173
MH: 08 0174MH: 08 0173downstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH, 3 (ACTIVE) AND 9 (POSSIBLY ACTIVE) O'CLOCK0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 08 017443.4 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 8"71.9 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES93.4 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 8"116.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES143.7 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 8"145.8 ft. CS - Crack Spiral, from 03 to 04 o'clock, within 8 inches of joint: YES167 ft. CS - Crack Spiral, from 09 to 11 o'clock, within 8 inches of joint: YES182.2 ft. CL - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES188.2 ft. CS - Crack Spiral, from 04 to 09 o'clock, within 8 inches of joint: YES194.9 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 8"202.7 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES214.8 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES220.8 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES226 ft. MGO - General Observation - ACTIVE CONNECTION AT MH, 9 O'CLOCK226 ft. AMH - Downstream Manhole, Survey Ends - 08 0173

Observation photos (9)

  • Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

    71.9 ft. - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    116.3 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Spiral, from 03 to 04 o'clock, within 8 inches of joint: YES

    145.8 ft. - Crack Spiral, from 03 to 04 o'clock, within 8 inches of joint: YES

  • Crack Spiral, from 09 to 11 o'clock, within 8 inches of joint: YES

    167 ft. - Crack Spiral, from 09 to 11 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES

    182.2 ft. - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES

  • Crack Spiral, from 04 to 09 o'clock, within 8 inches of joint: YES

    188.2 ft. - Crack Spiral, from 04 to 09 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    202.7 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    214.8 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    220.8 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (19)

DistanceCodeObservation
214.8CM
188.2CS
226MGOACTIVE CONNECTION AT MH, 9 O'CLOCK
145.8CS
43.4TFC
71.9CL
0MWM
167CS
194.9TFC
0MGOCONNECTION AT MH, 3 (ACTIVE) AND 9 (POSSIBLY ACTIVE) O'CLOCK
182.2CL
226AMH08 0173
0MWL
0AMH08 0174
202.7CM
93.4TF
143.7TFC
116.3CM
220.8CM

Properties (6)

custom_field_three
CRACKS
custom_field_two
3
customer
1
datetime
2021-05-17T23:04:30-07:00
documentation
PRO PIPE
is_lateral_inspection
false