Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 23, 2021, 06:26 AM
  • 15 0667_15 0666_06222021_234119.mp4

Date
06/22/2021
W/O
896249
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00602
PipeID
P12559
Time
11:26 PM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8991
Sewer Name
15 EL MONTE AVENUE TRUNK
City
TEMPLE CITY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
11
Purpose
Routine Assessment
Project
WO_896249_TV15005_JUN2021
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
15 0667
Downstream MH
15 0666
Dir. of Survey
Downstream
Length Surveyed
296 ft.
Total Length
296 ft.
Structural Index
3
Structural Quick
3K2K
Structural Rating
290
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
290
Pipe schematic from manhole 15 0667 to 15 0666
MH: 15 0667MH: 15 0666downstream0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. MWL - Water Level, 40 %of cross sectional area0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 15 06672.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.1 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start39 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"69.4 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"93 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"127 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: YES, 6"183.2 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 6", 6"195.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"294 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish294 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish296 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK296 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK296 ft. AMH - Downstream Manhole, Survey Ends - 15 0666

Observation photos (3)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: YES, 6"

    127 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: YES, 6"

Observations (17)

DistanceCodeObservation
195.1TFC
0MGOCONNECTION AT MH 9 O'CLOCK
93TFC
0MWL
2.1SAV
0MWM
294SSS
183.2TFA
39TFC
0AMH15 0667
69.4TFA
127TB
296MGOCONNECTION AT MH 3 O'CLOCK
296MGOCONNECTION AT MH 9 O'CLOCK
294SAV
296AMH15 0666
2.1SSS

Properties (6)

custom_field_three
AGGREGATE VISIBLE, SPALLING
custom_field_two
3
customer
1
datetime
2021-06-22T23:26:59-07:00
documentation
PRO PIPE
is_lateral_inspection
false