Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 18, 2021, 05:40 AM
  • B 0456_B 0455_06172021_224650.mp4

Date
06/17/2021
W/O
896150
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00093
PipeID
P08969
Time
10:40 PM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8942
Sewer Name
B JOINT OUTFALL B - UNIT 5C
City
PASADENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
11
Purpose
Routine Assessment
Project
RFIR_WO_896150_TV16079_JUN2021
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
21 in.
Width
57 in.
Upstream MH
B 0456
Downstream MH
B 0455
Dir. of Survey
Downstream
Length Surveyed
101.2 ft.
Total Length
101.2 ft.
Structural Index
3
Structural Quick
3C00
Structural Rating
54
O&M Index
2
O&M Quick
412C
O&M Rating
42
Overall Index
3
Overall Quick
Overall Rating
96
Pipe schematic from manhole B 0456 to B 0455
MH: B 0456MH: B 0455downstream0 ft. AMH - Upstream Manhole, Survey Begins - B 04560 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. MWL - Water Level, 30 %of cross sectional area2 ft. MGO - General Observation - MAG COATING THROUGHOUT2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start6.2 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start79.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"98.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish98.5 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish101.2 ft. AMH - Downstream Manhole, Survey Ends - B 0455

Observation photos (2)

  • General Observation - MAG COATING THROUGHOUT

    2 ft. - General Observation - MAG COATING THROUGHOUT

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    6.2 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

Observations (10)

DistanceCodeObservation
6.2SAP
98.5DAGS
2MGOMAG COATING THROUGHOUT
0AMHB 0456
79.1TFC
101.2AMHB 0455
98.5SAP
0MWM
0MWL
2DAGS

Properties (7)

additional_info
630069061721201
custom_field_three
AGGREGATE PROJECTING
custom_field_two
3
customer
1
datetime
2021-06-17T22:40:51-07:00
documentation
PRO PIPE
is_lateral_inspection
false