Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 25, 2021, 05:56 AM
  • 18 1114_18 1113A_06242021_230309.mp4

Date
06/24/2021
W/O
896154
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00711
PipeID
P14965
Time
10:56 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9055
Sewer Name
18 STAGE ROAD JUNCTION TRUNK
City
SANTA FE SPRINGS
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
31
Purpose
Routine Assessment
Project
WO_896154_TV18058_JUN2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
18 1114
Downstream MH
18 1113A
Dir. of Survey
Downstream
Length Surveyed
123.1 ft.
Total Length
123.1 ft.
Structural Index
3
Structural Quick
3C00
Structural Rating
66
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
66
Pipe schematic from manhole 18 1114 to 18 1113A
MH: 18 1114MH: 18 1113Adownstream0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 11147.7 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"12.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start44.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"93.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"123.1 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK123.1 ft. AMH - Downstream Manhole, Survey Ends - 18 1113A123.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (2)

  • Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"

    7.7 ft. - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    12.1 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (10)

DistanceCodeObservation
44.1TF
0MWM
7.7TB
0MWL
123.1MGOCONNECTION AT THE MH 9 OC'LOCK
12.1CM
0AMH18 1114
123.1AMH18 1113A
93.6TFC
123.1CM

Properties (6)

custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2021-06-24T22:56:04-07:00
documentation
PROPIPE
is_lateral_inspection
false