01 1226_01 1225_6262021_012811.mp4
2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING OUTER SURFACE
17.3 ft. - Water Mark, 50 %of cross sectional area
20 ft. - Fracture Circumferential, from 09 to 03 o'clock, within 8 inches of joint: YES - SLIGHT WITH PIPE CHIPPING
42.8 ft. - Surface Other, from 10 to 02 o'clock, within 8 inches of joint: YES - POSSIBLE VCP CORRISON
170.1 ft. - Surface Other, from 09 to 03 o'clock, within 8 inches of joint: YES - POSSIBLE VCP CORRISON
171.6 ft. - Roots Medium Joint, from 02 to 10 o'clock, 15 %, within 8 inches of joint: YESR, Start
183.3 ft. - Roots Medium Joint, from 02 to 07 o'clock, 25 %, within 8 inches of joint: YESR
190.7 ft. - Roots Medium Joint, from 03 to 06 o'clock, 25 %, within 8 inches of joint: YESR
266.1 ft. - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open
| Distance | Code | Observation |
|---|---|---|
| 188.1 | RMJ | — |
| 349.5 | FC | 40% HAIRLINE AT JOINTS |
| 166.5 | TF | Open |
| 221.7 | RMJ | — |
| 170.1 | SZ | POSSIBLE VCP CORRISON |
| 203.6 | RMJ | — |
| 10 | FC | H |
| 22.7 | FC | HAIRLINE AT JOINTS |
| 17.3 | MWM | — |
| 349.5 | FL | 10% SLIGHT AT JOINTS |
| 2 | SSS | BLISTERING OUTER SURFACE |
| 12.2 | FC | H |
| 242 | MWM | — |
| 349.5 | FL | 10% HAIRLINE AT JOINTS |
| 14.5 | FC | SL |
| 0 | MWM | — |
| 209 | RMJ | — |
| 22.7 | FL | HAIRLINE AT JOINTS |
| 333.9 | MWM | — |
| 179.5 | TFD | Open-60% ROOTS |
| 6.7 | FC | HAIRLINE |
| 22.7 | FL | SLIGHT AT JOINTS |
| 349.5 | FC | 40% SLIGHT AT JOINTS AT JOINTS |
| 17.3 | FC | SL |
| 171.6 | RMJ | — |
| 17.3 | FC | H |
| 349.8 | AMH | 2:30AM |
| 183.3 | RMJ | — |
| 218.9 | RMJ | — |
| 190.7 | RMJ | — |
| 253.4 | TF | Open |
| 349.5 | SSS | BLISTERING OUTER SUFACE |
| 349.5 | MGO | Conn. @ Mh, 9 O' Clock. Active |
| 92.7 | TF | Open |
| 12.2 | FC | SL |
| 0 | AMH | 1:30AM |
| 266.1 | TF | Open |
| 22.7 | FC | SLIGHT AT JOINTS |
| 5 | FC | SLIGHT |
| 349.5 | MGO | Conn. @ Mh, 12 O' Clock. Capped |
| 0 | MWL | — |
| 42.8 | SZ | POSSIBLE VCP CORRISON |
| 51.4 | TF | Open |
| 20 | FC | SLIGHT WITH PIPE CHIPPING |