- Date
- 06/26/2021
- W/O
- 0890879
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00217
- PipeID
- P02051
- Time
- 12:17 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H1856
- Sewer Name
- 01 SANTA FE AVENUE TRUNK
- City
- SOUTH GATE
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 01
- Page No.
- 07
- Purpose
- Capital Improvement Program Assesment
- Project
- 202106025MDM_SANTA_FE_AVENUE_TRUNK
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 15 in.
- Upstream MH
- 01 1226
- Downstream MH
- 01 1227
- Dir. of Survey
- Upstream
- Length Surveyed
- 70.9 ft.
- Total Length
- 70.9 ft.
- Structural Index
- 2
- Structural Quick
- 322A
- Structural Rating
- 30
- O&M Index
- 3
- O&M Quick
- 3311
- O&M Rating
- 10
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 40
Pipe schematic from manhole 01 1226 to 01 1227 Observation photos (3)

2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING OUTER LAYER

60.1 ft. - Roots Medium Joint, from 03 to 09 o'clock, 15 %, within 8 inches of joint: YESR, Start

70.5 ft. - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - 40% HAIRLINE AT JOINTS