- Date
- 06/28/2021
- W/O
- 0896102
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00518
- PipeID
- P06471
- Time
- 2:27 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H1853
- Sewer Name
- 05 SO HAWTHORNE-WARFIELD AV EXT TR, SECT 4
- City
- HAWTHORNE
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 19
- Purpose
- Capital Improvement Program Assesment
- Project
- 20210623MDM_SO_HAWTHORNE_WARFIELD_AV_EXT_TR_SECT_4
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 15 in.
- Upstream MH
- 05 2213
- Downstream MH
- 05 1260
- Dir. of Survey
- Downstream
- Length Surveyed
- 244.8 ft.
- Total Length
- 244.8 ft.
- Structural Index
- 2
- Structural Quick
- 4433
- Structural Rating
- 93
- O&M Index
- 3
- O&M Quick
- 3121
- O&M Rating
- 5
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 98
Pipe schematic from manhole 05 2213 to 05 1260 Observation photos (4)

2 ft. - Deposits Settled Other, 20 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start - SLUDGE

2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - PEELING OUTER SURFACE

10.5 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES - PEELING OUTER SURFACE

57.1 ft. - Fracture Multiple, from 08 to 02 o'clock, within 8 inches of joint: YES - SLIGHT