Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 26, 2021, 12:11 PM
  • 18 0291_18 0290_6262021_051315.mp4

Date
06/26/2021
W/O
0890847
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00702
PipeID
P14120
Time
5:11 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1857
Sewer Name
18 SHOEMAKER AVENUE TRUNK
City
NORWALK
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
25
Purpose
Capital Improvement Program Assesment
Project
20210626MDM_SHOREMAKER_AVENUE_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Upstream MH
18 0291
Downstream MH
18 0290
Dir. of Survey
Downstream
Length Surveyed
165.5 ft.
Total Length
165.5 ft.
Structural Index
2
Structural Quick
3428
Structural Rating
28
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
28
Pipe schematic from manhole 18 0291 to 18 0290
MH: 18 0291MH: 18 0290downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active0 ft. AMH - Upstream Manhole, Survey Begins - 5:15AM22.9 ft. MGP - General Photograph - 10" VCP24.5 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - HAIRLINE29.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped31.5 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES - SLIGHT32.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped41.8 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - SL49.8 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - SL64.7 ft. MMC - Material Change, Other (state in comments) - PIPE HAS A LINER74.5 ft. MMC - Material Change, Other (state in comments) - LINER FINISH79 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped81.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped101.1 ft. TB - Tap Break-In, at 03 o'clock, -, within 8 inches of joint: YES, 6" - Open107.4 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - SL107.4 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - SL119.7 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - H123.7 ft. FC - Fracture Circumferential, from 12 to 01 o'clock, within 8 inches of joint: YES - H127.9 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES - H128.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped131.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped149.3 ft. FL - Fracture Longitudinal, at 01 o'clock, within 8 inches of joint: YES - H157.1 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - SL161 ft. FC - Fracture Circumferential, from 11 to 01 o'clock, within 8 inches of joint: YES - SL165.5 ft. AMH - Downstream Manhole, Survey Begins - 5:35AM

Observation photos (2)

  • General Photograph - 10" VCP

    22.9 ft. - General Photograph - 10" VCP

  • Material Change, Other (state in comments) - PIPE HAS A LINER

    64.7 ft. - Material Change, Other (state in comments) - PIPE HAS A LINER

Observations (27)

DistanceCodeObservation
31.5FLSLIGHT
107.4FCSL
149.3FLH
22.9MGP10" VCP
81.8TFCCapped
107.4FCSL
49.8FCSL
32.2TFCCapped
131.8TFCCapped
165.5AMH5:35AM
0MWM
74.5MMCLINER FINISH
29.5TFCCapped
0MWL
24.5FCHAIRLINE
0MGOConn. @ Mh, 3 O' Clock. Active
101.1TBOpen
64.7MMCPIPE HAS A LINER
127.9FLH
0AMH5:15AM
157.1FLSL
161FCSL
119.7FCH
79TFCCapped
128.7TFCCapped
123.7FCH
41.8FCSL

Properties (6)

custom_field_three
SLIGHT FRACTURES
custom_field_two
3
customer
LACSD
datetime
2021-06-26T05:11:36-07:00
documentation
MARTIN,OLIVER 111,BARR
is_lateral_inspection
false