Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 10, 2021, 04:11 PM
  • H 0678_H 0677_06102021_092646.mp4

Date
06/10/2021
W/O
891214
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00941
PipeID
P11085
Time
9:11 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8983
Sewer Name
H JOINT OUTFALL H - UNIT 9B
City
PICO RIVERA
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
03
Purpose
Routine Assessment
Project
RFIR_WO_891214_TV18175_MAY2021
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
25 in.
Width
25 in.
Upstream MH
H 0678
Downstream MH
H 0677
Dir. of Survey
Downstream
Length Surveyed
277.9 ft.
Total Length
277.9 ft.
Structural Index
2
Structural Quick
312J
Structural Rating
111
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
2
Overall Quick
Overall Rating
115
Pipe schematic from manhole H 0678 to H 0677
MH: H 0678MH: H 0677downstream0 ft. AMH - Upstream Manhole, Survey Begins - H 06780 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 50 %of cross sectional area2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start7.1 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: NO, 15"11.9 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start265 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 24"277.9 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish277.9 ft. MWLS - Water Level, Sag in pipe, 20 %of cross sectional area277.9 ft. MSA - Survey Abandoned - DUE TO SAG277.9 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (4)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    11.9 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Water Level, Sag in pipe, 20 %of cross sectional area

    277.9 ft. - Water Level, Sag in pipe, 20 %of cross sectional area

  • Survey Abandoned - DUE TO SAG

    277.9 ft. - Survey Abandoned - DUE TO SAG

Observations (11)

DistanceCodeObservation
277.9SAP
277.9MWLS
265TFC
11.9SSS
7.1TFC
277.9MSADUE TO SAG
277.9SSS
2SAP
0AMHH 0678
0MWL
0MWM

Properties (6)

custom_field_three
AGGREGATE VISIBLE, SPALLING, SAG
custom_field_two
5
customer
1
datetime
2021-06-10T09:11:51-07:00
documentation
PRO PIPE
is_lateral_inspection
false