Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 2, 2021, 04:45 PM
  • H 0688_H 0687_06022021_095350.mp4

Date
06/02/2021
W/O
891214
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00941
PipeID
P11095
Time
9:45 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8976
Sewer Name
H JOINT OUTFALL H - UNIT 9B
City
PICO RIVERA
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
01
Purpose
Routine Assessment
Project
RFIR_WO_891214_TV18175_MAY2021
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
25 in.
Width
25 in.
Upstream MH
H 0687
Downstream MH
H 0688
Dir. of Survey
Upstream
Length Surveyed
165.9 ft.
Total Length
165.9 ft.
Structural Index
3
Structural Quick
3F2F
Structural Rating
165
O&M Index
2
O&M Quick
412E
O&M Rating
71
Overall Index
2
Overall Quick
Overall Rating
236
Pipe schematic from manhole H 0687 to H 0688
MH: H 0687MH: H 0688upstream0 ft. LL - Alignment Left, 10 %, Finish0 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish0 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish0 ft. AMH - Upstream Manhole, Survey Ends - H 06882.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish14.3 ft. LL - Alignment Left, 10 %, Start163.2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start163.2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start163.2 ft. MGO - General Observation - MAG COAT163.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start165.9 ft. MWL - Water Level, 25 %of cross sectional area165.9 ft. AMH - Downstream Manhole, Survey Begins - H 0687165.9 ft. MWM - Water Mark, 30 %of cross sectional area

Observation photos (4)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.7 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.7 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Observation - MAG COAT

    2.7 ft. - General Observation - MAG COAT

  • Alignment Left, 10 %, Start

    151.6 ft. - Alignment Left, 10 %, Start

Observations (13)

DistanceCodeObservation
163DAGS
165.9LL
165.9SAV
165.9SSS
151.6LL
2.7SAV
0MWL
0AMHH 0687
2DAGS
2.7SSS
2.7MGOMAG COAT
165.9AMHH 0688
0MWM

Properties (6)

custom_field_three
AGGREGATE VISIBLE.SPALLING
custom_field_two
3
customer
1
datetime
2021-06-02T09:45:53-07:00
documentation
PRO PIPE
is_lateral_inspection
false