- Date
- 06/14/2021
- W/O
- 896149
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00006
- PipeID
- P00197
- Time
- 9:56 PM
- Certificate
- U-508-7069
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K8898
- Sewer Name
- 08 FIGUEROA STREET TRUNK
- City
- GARDENA
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 08
- Page No.
- 02
- Purpose
- Routine Assessment
- Project
- RFIR_WO_896149_TV08173_JUN2021
- Sewer Type
- Gravity
- Material
- NRCP
- Shape
- Circular
- Height
- 10 in.
- Width
- 8 in.
- Upstream MH
- 08 0141
- Downstream MH
- 08 0140
- Dir. of Survey
- Downstream
- Length Surveyed
- 354.1 ft.
- Total Length
- 354.1 ft.
- Structural Index
- 3
- Structural Quick
- 3L00
- Structural Rating
- 198
- O&M Index
- 2
- O&M Quick
- 2M00
- O&M Rating
- 140
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 338
Pipe schematic from manhole 08 0141 to 08 0140 Observation photos (2)

2.1 ft. - Deposits Attached Encrustation, 10 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Start

26.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start