Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 15, 2021, 05:17 AM
  • 08 0140_08 0139_06142021_223126.mp4

Date
06/14/2021
W/O
896149
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00006
PipeID
P00196
Time
10:17 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8898
Sewer Name
08 FIGUEROA STREET TRUNK
City
GARDENA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
02
Purpose
Routine Assessment
Project
RFIR_WO_896149_TV08173_JUN2021
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
10 in.
Width
15 in.
Upstream MH
08 0140
Downstream MH
08 0139
Dir. of Survey
Downstream
Length Surveyed
406.5 ft.
Total Length
406.5 ft.
Structural Index
3
Structural Quick
413O
Structural Rating
247
O&M Index
2
O&M Quick
2O00
O&M Rating
162
Overall Index
3
Overall Quick
Overall Rating
409
Pipe schematic from manhole 08 0140 to 08 0139
MH: 08 0140MH: 08 0139downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 08 01400 ft. MWL - Water Level, 15 %of cross sectional area2.4 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.4 ft. DAE - Deposits Attached Encrustation, 10 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start52.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"147.1 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES148.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"252.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"353.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"406.4 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish406.4 ft. DAE - Deposits Attached Encrustation, 10 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Finish406.5 ft. AMH - Downstream Manhole, Survey Ends - 08 0139

Observation photos (3)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.4 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Encrustation, 10 %of cross sectional area, from 08 to 04 o'clock,  , within 8 inches of joint: YES, Start

    2.4 ft. - Deposits Attached Encrustation, 10 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    147.1 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

Observations (13)

DistanceCodeObservation
406.4SAV
353.3TFC
52.2TF
2.4SAV
0MWM
147.1FM
0AMH08 0140
406.5AMH08 0139
2.4DAE
252.8TFC
406.4DAE
148.4TFC
0MWL

Properties (7)

additional_info
630074061421201
custom_field_three
AGGREGATE VISIBLE
custom_field_two
3
customer
1
datetime
2021-06-14T22:17:47-07:00
documentation
PROPIPE
is_lateral_inspection
false