Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 28, 2021, 03:18 PM
  • 15 0238_15 0237_05282021_085559.mp4

Date
05/28/2021
W/O
890822
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00627
PipeID
P12160
Time
8:18 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8970
Sewer Name
15 SAN JOSE CREEK TRUNK
City
HACIENDA HEIGHTS
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
33
Purpose
Routine Assessment
Project
WO_890822_TV15001_MAY2021
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
36 in.
Width
36 in.
Upstream MH
15 0238
Downstream MH
15 0237
Dir. of Survey
Downstream
Length Surveyed
695.7 ft.
Total Length
695.7 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
3
O&M Quick
3323
O&M Rating
15
Overall Index
3
Overall Quick
Overall Rating
18
Pipe schematic from manhole 15 0238 to 15 0237
MH: 15 0238MH: 15 0237downstream0 ft. AMH - Upstream Manhole, Survey Begins - 15 02380 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area5.8 ft. MGO - General Observation - MAG COAT5.8 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start15.8 ft. OBZ - Obstacles Other, 10 %of cross sectional area, at 06 o'clock - UNDER FLOW89.1 ft. OBZ - Obstacles Other, 5 %of cross sectional area, at 06 o'clock - UNDER FLOW262.1 ft. TBC - Tap Break-In Capped, at 12 o'clock, -, within 8 inches of joint: NO, 8"469.5 ft. DAE - Deposits Attached Encrustation, 15 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES469.5 ft. ID - Infiltration Dripper, from 12 to 01 o'clock, within 8 inches of joint: YES662.5 ft. DAE - Deposits Attached Encrustation, 15 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES662.6 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 8"695.7 ft. MSA - Survey Abandoned - RAN OUT OF CABLE695.7 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish695.7 ft. MGO - General Observation - RAN OUT OF CABLE

Observation photos (8)

  • General Observation - MAG COAT

    5.8 ft. - General Observation - MAG COAT

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    5.8 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Obstacles Other, 10 %of cross sectional area, at 06 o'clock - UNDER FLOW

    15.8 ft. - Obstacles Other, 10 %of cross sectional area, at 06 o'clock - UNDER FLOW

  • Obstacles Other, 5 %of cross sectional area, at 06 o'clock - UNDER FLOW

    89.1 ft. - Obstacles Other, 5 %of cross sectional area, at 06 o'clock - UNDER FLOW

  • Tap Break-In Capped, at 12 o'clock, -, within 8 inches of joint: NO, 8"

    262.1 ft. - Tap Break-In Capped, at 12 o'clock, -, within 8 inches of joint: NO, 8"

  • Deposits Attached Encrustation, 15 %of cross sectional area, from 08 to 04 o'clock,  , within 8 inches of joint: YES

    469.5 ft. - Deposits Attached Encrustation, 15 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES

  • Infiltration Dripper, from 12 to 01 o'clock, within 8 inches of joint: YES

    469.5 ft. - Infiltration Dripper, from 12 to 01 o'clock, within 8 inches of joint: YES

  • Deposits Attached Encrustation, 15 %of cross sectional area, from 08 to 04 o'clock,  , within 8 inches of joint: YES

    662.5 ft. - Deposits Attached Encrustation, 15 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES

Observations (15)

DistanceCodeObservation
5.8MGOMAG COAT
89.1OBZUNDER FLOW
695.7MSARAN OUT OF CABLE
469.5DAE
695.7SAP
15.8OBZUNDER FLOW
262.1TBC
5.8SAP
662.5DAE
469.5ID
0AMH15 0238
695.7MGORAN OUT OF CABLE
662.6TFC
0MWL
0MWM

Properties (6)

custom_field_three
AGGREGATE PROJECTING
custom_field_two
3
customer
1
datetime
2021-05-28T08:18:45-07:00
documentation
PRO PIPE
is_lateral_inspection
false