Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 18, 2021, 05:23 AM
  • 15 0268_15 0267_05172021_224027.mp4

Date
05/17/2021
W/O
890822
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00627
PipeID
P12191
Time
10:23 PM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8915
Sewer Name
15 SAN JOSE CREEK TRUNK
City
CITY OF INDUSTRY
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
37
Purpose
Routine Assessment
Project
WO_890822_TV15001_MAY2021
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
15 0267
Downstream MH
15 0268
Dir. of Survey
Upstream
Length Surveyed
467.1 ft.
Total Length
467.1 ft.
Structural Index
3
Structural Quick
3M00
Structural Rating
204
O&M Index
2
O&M Quick
2Q00
O&M Rating
182
Overall Index
2
Overall Quick
Overall Rating
386
Pipe schematic from manhole 15 0267 to 15 0268
MH: 15 0267MH: 15 0268upstream0 ft. AMH - Upstream Manhole, Survey Ends - 15 02681.8 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish1.8 ft. MGO - General Observation - COCKROACHES IN MANHOLE1.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"105.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"258 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"339.7 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start362.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"431.9 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"433.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"459.2 ft. MWM - Water Mark, 25 %of cross sectional area459.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start465.1 ft. MGO - General Observation - MAG COATING THROUGHOUT467.1 ft. MWL - Water Level, 5 %of cross sectional area467.1 ft. AMH - Downstream Manhole, Survey Begins - 15 0267467.1 ft. MGO - General Observation - COCKROACHES IN MANHOLE

Observation photos (5)

  • General Observation - COCKROACHES IN MANHOLE

    0 ft. - General Observation - COCKROACHES IN MANHOLE

  • General Observation - MAG COATING THROUGHOUT

    2 ft. - General Observation - MAG COATING THROUGHOUT

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    7.9 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    127.4 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES IN MANHOLE

    465.3 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (17)

DistanceCodeObservation
7.9MWM
465.3SAV
0MWL
0AMH15 0267
465.3MGOCOCKROACHES IN MANHOLE
7.9DAGS
465.3DAGS
0MGOCOCKROACHES IN MANHOLE
361.2TF
35.2TBA
209.1TFC
127.4SAV
458.1TFC
33.7TFC
2MGOMAG COATING THROUGHOUT
104.3TFC
467.1AMH15 0268

Properties (7)

additional_info
630069051721201
custom_field_three
VISIBLE AGGREGATE
custom_field_two
3
customer
1
datetime
2021-05-17T22:23:03-07:00
documentation
PRO PIPE
is_lateral_inspection
false